Existing Roof Type: Standing Seam Metal Roof

Product Manufacturer: Henry

Roof pitch: 2”

Roof Use: Mill Work

Duration of Job: Two Weeks

Size: 6,000 sq. ft.

Height: 30’

Warranty: 20-years material warranty

Special Project Circumstances: There was some HVAC exhaust vents on the roof that needed to be removed before restoring the roof.

Condition/Problem: Through the years, the metal shifted, opening seams, which allowed water to enter the building. The movement and building vibrations also caused the fasteners used to hold the roof in place to get loose.

Solution: The entire roof was completely swept, debris removed, and it was power washed to prepare the roof for the application of the Henry PGE System. Identified problem areas, penetrations, and seams were reinforced. Then the PGE-988 was applied to the entire roof. Given the necessary amount of time to cure, we returned to apply secondary touch up at areas we believed were needed.

Result: A seamless, white reflective, Energy Star rated, silicon system that will last more than 20 years.